MINVON SP200 Series Single Phase 220V Solar Pumping Inverter for Agricultural Irrigation

  • Model Type:SP200 Series
  • Output Voltage(V):1PH 220V, 3PH 220V, 3PH 380V
  • Rated Power(KW):0.75kw-132kw
  • Rated Input Current (A):5A-240A
  • Rated Output Current(A):2.5A-250A
  • Output Type:Single/Three Phase
  • Inverter Type:Solar Pump Drive
  • OEM:Acceptable
Book Now



KEY FEATURES

  • Support single-phase 220V, three-phase 220V and three-phase 380V water pumps.

  • Good usability and simple operation. Automatic startup of the photovoltaic water pump can be realized only by connecting the photovoltaic cell panel to the inverter without setting any parameters.

  • Multiple protection measures, such as overvoltage protection, output module failure, over-temperature, over-voltage, over-current, overload and other protection functions.

  • Water level control logic, avoid dry run and have full water level protection function

TECHNICAL SPECIFICATION

Specification Description3AC 220V3AC 380V
Maximum input DC voltage410V DC900V DC
Recommended DC input yoltage range220-370V DC420-720V DC
Recommended input working voltage305V DC540V DC
The number of Input port11
Output frequency range0-600Hz0-600Hz
Cooling methodAir coolingAir cooling
StandardCECE

1.1 0utput 3AC 380V

Maximum input DC voltage800VDC
Recommended DC input yoltage range420~720VDC
Recommended input working voltage540VDC
The number of Input port1
Rated output voltage3AC 380V
Output frequency range0~600Hz
Cooling methodAir cooling
AltitudeThis controller should be installed with altitude oflower than 1000m.
It will be degraded when the altitude higher than 1000m. For details, rated output current should be degraded 1% for every 100m
StandardCE

1.2 Output 3AC 220V

Maximum input DC voltage410VDC
Recommended DC input voltage range220-370VDC
Recommended input working voltage305VDC
The number of Input port1
Rated output voltage3AC 220V
Output frequency range0~600Hz
Cooling methodAir cooling
AltitudeThis controller should be installed with altitude oflower than 1000m. It will be degraded when the altitude higher than 1000m. For details, rated output current should be degraded 1% for every 100m
StandardCE




Model No.Output Voltage(V)Rated Power(kW)Rated Input
Current(A)
Rated Output
Current(A)
SP200-0R7G-SS21PH 2200.7514.27
SP200-1R5G-SS21PH 2201.52310
SP200-2R2G-SS21PH 2202.23516
SP200-0R7G-S23PH 2200.759.34.2
SP200-1R5G-S23PH 2201.514.27
SP200-2R2G-S23PH 2202.22310
SP200-0R7G-23PH 2200.7554.5
SP200-1R5G-23PH 2201.57.77
SP200-2R2G-23PH 2202.21110
SP200-004G-23PH 22041716
SP200-5R5G-23PH 2205.52120
SP200-7R5G-23PH 2207.53130
SP200-011G-23PH 380114342
SP200-015G-23PH 380155655
SP200-018G-23PH 380187170
SP200-0R7G-43PH 3800.753.42.5
SP200-1R5G-43PH 3801.553.7
SP200-2R2G-43PH 3802.25.85
SP200-004G-43PH 3804109
SP200-5R5G-43PH 3805.51513
SP200-7R5G-43PH 3807.52017
SP200-011G-43PH 380112625
SP200-015G-43PH 380153532
SP200-018G-43PH 380183837
SP200-022G-43PH 380224645
SP200-030G-43PH 380306260
SP200-037G-43PH 380377675
SP200-045G-43PH 380459090
SP200-055G-43PH 38055105110
SP200-075G-43PH 38075140150
SP200-090G-43PH 38090160176
SP200-110G-43PH 380110210212
SP200-132G-43PH 380132240250





  









































SP200-3.pngSP200-2.pngSP200-4.png

 